Transformer Test Equipment for Utilities, Substations and Electrical Contractors
Wrindu supplies transformer test equipment for utilities, substations and electrical contractors: winding resistance meters, transformer turn ratio testers, dielectric loss testers and the insulation and resistance instruments used alongside them.
- Warranty
- 12-month warranty

Which Transformer Test Equipment Wrindu Supplies
Wrindu is the brand name of Rui Du Mechanical and Electrical (Shanghai) Co., Ltd., established in 2014 in Shanghai. The transformer test equipment range covers winding resistance meters, transformer turn ratio testers, dielectric loss testers, and the insulation resistance and grounding instruments used alongside them in the same test programmes.
Products have been exported to more than 120 countries, with South Asia, Southeast Asia and Africa as the main markets. Tell the sales team the transformer type, the voltage level and the tests you need, and the reply is a selection proposal. Reach the team through the inquiry form.

Transformer tester, view 2 
Transformer tester, view 3
Transformer test equipment models and specifications
| Parameter | Value |
|---|---|
| Picture | |
| Model | RDTBT |
| Voltage | Measuring range 1V ~ 500V, Accuracy: 0.1 |
| Current | Measuring range 100mA ~ 5A, Accuracy: 0.1 |
| Power | U*I, Accuracy: 0.2 |
| Working frequency | 50Hz |
| Power factor | 0.050 ~ 0.999, Accuracy: 0.2 |
| Frequency | 45 ~ 65Hz, Accuracy 0.1 |
| Test voltage | Uab, Ubc, Uac |
| Test current | Ia, Ib, Ic |
| No-load current Io% | No-load current Io% |
| No-load loss Po, load loss Pk | No-load loss Po, load loss Pk |
| Impedance voltage UK, power factor PF | Impedance voltage UK, power factor PF |
| Three-phase voltage average U, three-phase current average I | Three-phase voltage average U, three-phase current average I |
| Model | RD6000A | ||
|---|---|---|---|
| Accuracy | Cx ±(reading×1%+1pF); tgδ ±(reading×1%+0.00040) | ||
| Anti-interference index | Frequency conversion anti-interference, in 200% interference can still achieve the above accuracy | ||
| Capacitance range | Internal high voltage: 3pF60000pF/10kV; 60pF1μF/0.5kV | ||
| Capacitance range | External high voltage: 3pF1.5μF/10kV; 60pF30μF/0.5kV | ||
| Capacitance range | Resolution: maximum to 0.001pF, 4 significant digits | ||
| tgδ range | No limitation, resolution 0.001%, capacitance, inductance, or resistance can be automatically identified | ||
| Test current range | 10μA~5A | ||
| Internal high voltage | Voltage setting range: 100V~10kV adjustable, resolution 1V | ||
| Internal high voltage | Voltage setting range: 100V~10kV adjustable, resolution 1V | External high voltage | UST test mode: Maximum test current 5A, frequency 40~70Hz |
| GST test mode: Maximum test voltage/current 10kV/5A, frequency 40~70Hz | |||
| Test frequency | Single frequency 40.0~70.0Hz, resolution 0.1Hz | External high voltage | |
| Test frequency | Automatic dual variable frequency set at will (from 50±0.1Hz to 50±10Hz) | ||
| Test frequency | Automatic dual variable frequency set at will (from 60±0.1Hz to 60±10Hz) | ||
| CVT self-exciting low voltage output | Output voltage 3-50V, output current 3-30A | ||
| Measuring duration | About 40s, depending on the measuring method | ||
| Power Supply | 220V AC, 50Hz ± 1% | ||
| Interface | RS232, USB | ||
| Printer | Mini-type thermal printer | ||
| Ambient temperature | -10℃~50℃ | ||
| Relative humidity | <90% |
| Parameter | Value |
|---|---|
| AC impedance | 0~999.9Ω, level 0.5 |
| AC voltage | 0~600V, level 0.5 |
| AC current | 0~120A, level 0.5 |
| Active power | 0~72KW, level 1.0 |
| Frequency | 45~75Hz,level 0.2 |
| Working power supply | 220VAC,50Hz |
| No. | Technical Parameter | Specification |
|---|---|---|
| 1 | Scanning Mode | Linear Scan: 1kHz–2MHz Sectional Scan: 0.5kHz–1MHz Sub-ranges: 0.5kHz–10kHz, 10kHz–100kHz, 100kHz–500kHz, 500kHz–1000kHz |
| 2 | Amplitude Measurement Range | -100dB to +20dB |
| 3 | Amplitude Measurement Accuracy | ±1dB |
| 4 | Scan Frequency Accuracy | 0.01% |
| 5 | Signal Input Impedance | 1MΩ |
| 6 | Signal Output Impedance | 50Ω |
| 7 | Same-Phase Repeatability | ≥99.5% |
| Parameter | Value |
|---|---|
| Parameter | Specification |
| Power Supply | 200V–230V AC, 50/60 Hz |
| Output Voltage | 0–200V |
| Optional Output Voltage | 0–2kV / 0–10kV |
| Frequency Range | 0.1 mHz–10 kHz |
| Output Current | ±50 mA |
| Capacitance Range | 100 pF–1 μF |
| Capacitance Accuracy | ±0.5% of reading + 1 pF |
| tan δ Range | 0–100 (0–10000%) |
| tan δ Accuracy | <0.5% + 0.0002 (45–70 Hz, C > 300 pF) |
| <1% + 0.0003 (1 mHz–100 Hz, C > 1000 pF) | |
| <2% + 0.0005 (100 Hz–1 kHz, C > 1000 pF) | |
| Operating Temperature | -10℃ to +55℃ |
| Dimensions | 320 mm × 340 mm × 110 mm |
| Weight | 6.2 kg (excluding test leads) |
What Transformer Testing Covers
Transformer testing is a group of measurements taken together. Insulation resistance shows moisture, dirt or damaged insulation before other tests run. Winding resistance shows the condition of connections, strands and tap contacts. Turns ratio and vector group confirm the windings are connected as designed. Short-circuit impedance, magnetizing current and dielectric loss show how the core, windings and insulation behave.
- Insulation resistance: insulation resistance testers, including the digital insulation resistance tester used on transformers, motors and cables.
- Winding resistance: the dual-channel winding resistance meter.
- Turns ratio, vector group, PT and CT ratio and polarity: the transformer turn ratio tester.
- Dielectric loss: dielectric loss testers used on transformers, bushings, capacitors and arresters.
- Transformer performance: the RDTBT series transformer test bench, designed for performance testing of power and distribution transformers.
Sweep Frequency Response Analysis (SFRA) Transformer Test
Winding deformation changes the frequency response of a transformer winding. The RDBX-H sweep frequency response analyzer card is the instrument for transformer winding deformation testing, and its specification table on this page lists what the instrument records.
The RDGYB-JD1000 dielectric frequency response analyzer combines FDS and PDC technologies to evaluate insulation condition, moisture content, oil conductivity and aging performance; its own specification table on this page lists the measurement parameters. Send the transformer details and the tests you plan for a selection proposal.
Winding Resistance Test of Transformer Windings
A winding resistance test of a transformer finds loose connections, broken strands, tap changer contact problems and winding conditions that appear as resistance differences between phases or against earlier records. A reading that sits away from the other phases, or from the commissioning record, points to a joint or contact that needs attention.
The method is a DC injection: direct current is injected into the winding, and once the current has settled the steady-state voltage drop gives the resistance. Readings are corrected to a reference temperature, then compared between phases, between tap positions and against earlier records.
Transformer Winding Resistance Testers: Selection Points
The first question when choosing a transformer winding resistance tester is the resistance range needed for the windings being measured. A stable DC source matters when the winding is highly inductive, discharge protection keeps leads safe to remove once a reading is taken, and data storage with reporting makes trending practical.
In maintenance work a winding resistance tester measures DC resistance of transformer windings across tap positions, compares phases and trends readings over the service life of the unit. Wrindu’s dual-channel winding resistance meter uses a dual-channel design that can synchronize the detection of two resistance values. The right instrument for a job depends on the windings and connections being tested.
Transformer Testing Equipment from Wrindu
Wrindu supplies transformer and power testing instruments for these measurements. The transformer turn ratio tester covers transformer turn ratio, vector group, and PT and CT ratio and polarity testing, with fast testing speed and high measurement accuracy. Dielectric loss testers serve transformers, bushings, capacitors and arresters, and insulation and resistance testers support the same test programmes.
Rui Du Mechanical and Electrical (Shanghai) Co., Ltd. was established in 2014 and is located in Shanghai, with over 10 years of professional experience in global market service. Wrindu provides OEM and ODM customized products, and many listings on its Alibaba store show a minimum order of 1 set.
Power Transformer Testing for Substations and Utilities
Power transformer testing at a substation brings those measurements together: insulation resistance, winding resistance, turns ratio and vector group, short-circuit impedance, dielectric loss of windings and bushings, and oil-related checks. The transformer turn ratio tester covers turn ratio and vector group, the dielectric loss test equipment is used on transformers, bushings, capacitors and arresters, and oil checks sit with the oil testers range.
After pre-delivery inspection and packing, delivery time is confirmed with the quotation, by FOB terms (nearest port: Shanghai) or express delivery. The 12-month warranty covers free training, manuals, complaint response and software upgrades, and the after-sales team offers installation, training and maintenance support, with maintenance and spare parts available afterwards.
How an order runs
- Send your requirements
- The equipment you need to test, its voltage level and the tests you plan to run.
- Selection and quotation
- Wrindu proposes matching tester models and accessories and sends a quotation.
- Inspection and delivery
- Equipment is inspected and packed before delivery; the delivery time is confirmed with the quotation.
- Warranty and training
- During the 12-month warranty, Wrindu provides free training, manuals, complaint response and software upgrades.
Request a quotation
Send the test object and voltage level; we will propose matching tester models.
Or write to sales@hipottestequipment.com