Circuit Breaker Analyzer for High-Voltage Breaker Testing
Wrindu supplies high-voltage and power testing equipment from Shanghai, including instruments for breaker mechanical testing and contact or loop resistance checks. This page explains where breaker analysis fits in maintenance and which Wrindu models match common test needs.
- Warranty
- 12-month warranty

Breaker Mechanical and Dynamic Testing Checks
A circuit breaker analyzer evaluates the mechanical and dynamic characteristics of high-voltage breakers. In general field use, it records timing, travel and contact-synchronization checks so maintenance teams can compare breaker operation with expected behaviour. Wrindu, the brand of Rui Du Mechanical and Electrical (Shanghai) Co., Ltd., supplies power testing equipment for these tasks. The RDGC-8C Switch Dynamic Characteristics Test Set accurately measures the mechanical characteristics of high voltage circuit breakers, including less oil, more oil, vacuum and SF6 types.
For breaker work that also requires contact and loop resistance checking, Wrindu offers related contact resistance testers and loop resistance testers. These are separate checks from mechanical testing: they assess the current path rather than the breaker movement. Use the breaker type and the maintenance task to decide the test order, then match the instrument to the measurement needed. For SF6 breaker work, related gas checks can be supported with SF6 gas analyzers.

Circuit breaker analyzer, view 2 
Circuit breaker analyzer, view 3
Circuit breaker analyzer models and specifications
| Parameter | Value |
|---|---|
| Parameter | Specification |
| Test Current | 30A, 50A, 80A, 100A, 150A, 200A |
| Range | 30A: 0 ~ 20mΩ 50A: 0 ~ 10mΩ 80A: 0 ~ 8mΩ 100A: 0 ~ 5mΩ 150A: 0 ~ 2mΩ 200A: 0 ~ 1mΩ |
| Resolution | Minimum 0.1µΩ |
| Accuracy | ± (0.5% rdg + 1µΩ) |
| Testing Time | Fast, 10s, 20s, 30s, 40s, 50s, 60s (Timing test applicable to 30A, 50A, 80A, 100A) |
| Power | ≤ 500W |
| Port | RS232, charging, USB |
| Working Mode | Constant current, limited voltage; output voltage about 2V |
| Power Supply | Rechargeable lithium batteries; Charger input 100-240VAC, 50Hz/60Hz |
| Service Temperature | -10 ~ 50℃ |
| Relative Humidity | ≤ 90%, no condensation |
| Parameter | Value |
|---|---|
| Parameter | Specification |
| Test Current | 25A, 50A, 100A, 150A, 200A |
| Measurement Range | 50–300 mΩ (25A)30–140 mΩ (50A)0–50 mΩ (100A)0–20 mΩ (150A)0–10 mΩ (200A) |
| Resolution | Minimum 0.1 µΩ |
| Accuracy | ± (0.5% rdg + 1 µΩ) |
| Testing Time | Fast, 10 s, 20 s, 30 s, 40 s, 50 s, 60 s |
| Power Consumption | ≤ 2000 W |
| Working Mode | Constant current with limited voltage, output voltage up to 10 V |
| Working Power Supply | AC 220 V ±10%, 50 Hz / 60 Hz |
| Operating Temperature | -10 °C to 50 °C |
| Relative Humidity | ≤ 90%, non-condensing |
| Parameter | Value |
|---|---|
| Model | RDZK-IV |
| Test object | various types of vacuum switch tubes. |
| Detection method | the new excitation coil is used to measure the vacuum tube without disassembly. |
| Detection range | 10 -5 ~10 -1 Pa |
| Measurement accuracy | 10 -5 ~10 -4 Pa,15% 10 -4 ~10 -3 Pa, 15% 10 -3 ~10 -2 Pa, 10% 10 -2 ~10 -1 Pa, 10% |
| Magnetic field voltage | 1700V |
| The high voltage of the pulsed electric field | 30KV |
| Opening distance of switch tube during a vacuum test | Normal opening distance |
| Operating environment | – 20 ℃~ 40 ℃ |
| Main engine weight | 24 kg |
| Overall dimension | 420 mm × 320 mm × 280 mm |
| Parameter | Value |
|---|---|
| Picture | |
| Model | RDGC-8C |
| Time Measurement | 12 natural opening (closing) time Different periods in the opening (closing) phase The difference between different phases of switching (closing) (1 ~ 99ms) Closing (opening) bounce time (bounce number) Different testing range: 1ms ~ 99ms, resolution: 0.01ms; Internal trigger test range: 1ms ~ 999ms, resolution: 0.01ms, 1000ms ~ 9999ms, resolution: 0.1ms, 10000ms ~ 200000ms resolution: 1ms. External trigger test range: 0.01ms ~ 200s Accuracy within 1000ms: 0.05%±0.1ms |
| Closing Resistance Measurement | 6 natural opening (closing) time Different periods in the opening (closing) phase The switching (closing) phase is different Closing resistance input time, resistance value |
| Measuring Range | 30 ~ 10KΩ, resolution 0.1Ω, accuracy: ≤1%±2 words |
| Dynamic Resistance Measurement | Current output 200A, Measurement range: 0-50mΩ, Accuracy: ≤0.5%±0.5uΩ. |
| Speed Measurement | Just-minute (just-combined) speed The average speed of a specified period (travel or Angle) |
| Speed Measuring Range | 0.1mm sensor 0.01 ~ 15.00m/s 345° Angle sensor 0.01 ~ 20.00m/s Laser sensor: 0.01 ~ 15.00m/s (optional) |
| Stroke Measurement | Stroke of moving contact (stroke) (optional for 3-way stroke measurement) Contact stroke (opening distance) Over travel Overstrike or rebound stroke |
| Coil Current Measurement Range | Maximum current 30A, resolution: 0.01A. |
| Coil Resistance Measurement Range | 0 ~ 2000Ω, resolution: 0.01Ω. |
| Instrument Power Supply | AC220V ± 10%; 50 HZ plus or minus 10%. |
| DC Power Output | DC6 ~ 270V continuous adjustable, DC24V≤15A (short time), DC220V≤ 20A(short time). |
| External Trigger Voltage | AC/DC10-300V, current ≤120A |
| Measuring Range Of Isolation Switch | Voltage output: (1) DC6 ~ 270V (adjustable); (2) Power output time: 0.01-20 seconds (can be set); (3) The maximum acquisition time of fracture signal is 200s (4) Break close measurement, opening time, three-phase different periods, bounce time and number |
| Host Volume | 400×380×285mm |
| Operating Environment | -20℃~+50℃ |
| Relative Humidity | ≤90% |
Micro Ohmmeter or Contact Resistance Tester: Which Do I Need?
A micro ohmmeter measures very low resistance, typically at breaker contacts, busbar joints and switchgear connections. The test is a general resistance check of the current path; it does not describe breaker timing or travel. In breaker and switchgear maintenance, the result helps confirm that contact and loop resistance are stable after assembly, service or joint work. Wrindu supplies contact resistance testers for this measurement intent, including models listed below, and the contact page can route an inquiry by breaker type.
A contact resistance tester measures contact and loop resistance in switches and switchgear. Wrindu offers the RDHL-100H and RDHL-200H contact resistance testers; the RDHL-200H is designed for measuring loop resistance of switching control equipment using high-frequency switching power supply technology and digital circuit technology. The RDHL-100P Earth Loop Impedence Testers is a high-precision device for measuring loop resistance in switchgear, with features for high-voltage switch maintenance and testing. The Contact Resistance Measurement Kit is for on-site high-voltage switch maintenance and DC resistance testing in cable lines.
- RDHL-100H: available model for contact resistance checking
- RDHL-200H: designed for loop resistance of switching control equipment using high-frequency switching power supply technology and digital circuit technology
- RDHL-100P Earth Loop Impedence Testers: high-precision loop resistance in switchgear, with features for high-voltage switch maintenance and testing
- Contact Resistance Measurement Kit: for on-site high-voltage switch maintenance and DC resistance testing in cable lines
What Does a Breaker Analyzer Measure?
Circuit breaker analyser is a spelling variant of circuit breaker analyzer, with the same buyer intent. It refers to the same explanation of mechanical and dynamic breaker testing: general timing, travel and contact-synchronization checks. The Wrindu model for this work is the RDGC-8C Switch Dynamic Characteristics Test Set, which accurately measures the mechanical characteristics of high voltage circuit breakers, including less oil, more oil, vacuum and SF6 types. The spelling does not indicate a different test method or a separate instrument class.
When selecting a breaker analyzer for field maintenance, consider the breaker type to be tested and whether the work needs mechanical and dynamic testing plus contact or loop resistance checks. Consider also the support available for installation, training and maintenance. Wrindu provides installation, training and maintenance support through its after-sales team; maintenance and spare parts remain available after the 12-month warranty. The RDGC-8C is the Wrindu model for mechanical characteristics of less oil, more oil, vacuum and SF6 high-voltage circuit breakers.
How an order runs
- Send your requirements
- The equipment you need to test, its voltage level and the tests you plan to run.
- Selection and quotation
- Wrindu proposes matching tester models and accessories and sends a quotation.
- Inspection and delivery
- Equipment is inspected and packed before delivery; the delivery time is confirmed with the quotation.
- Warranty and training
- During the 12-month warranty, Wrindu provides free training, manuals, complaint response and software upgrades.
Request a quotation
Send the test object and voltage level; we will propose matching tester models.
Or write to sales@hipottestequipment.com