Protection Relay Test Set Range for Utilities and Substations
A protection relay test set injects voltage and current into protective relays to confirm they pick up, time and trip correctly. Wrindu supplies the RDJB series and the RDHG-D CT PT Analyzer for utility, substation and contractor protection testing work.
- Warranty
- 12-month warranty

Selecting a Protection Relay Test Set for Utility and Substation Work
A protection relay test set tests protective relays and secondary circuits by applying voltage and current to relay inputs and reading how the relay responds. Selection starts with phase count, then moves to output type, portability and the protection functions a team needs on site or in the workshop. Wrindu supplies the RDJB series microcomputer protection relay tester, which integrates microelectronic technology and offers high performance, cost-effectiveness and reliability, and the specification tables on this page list the models and their parameters.
Wrindu supplies these units for utility, substation and contractor protection work, and a quotation can be requested through the inquiry form on this page, the contact page or a sales email.

Relay protection tester, view 2 
Relay protection tester, view 3
Protection relay test set models and specifications
| Model | RDSL-82-2000A | RDSL-82-5000A | RDSL-82-6000A | RDSL-82-10000A |
|---|---|---|---|---|
| Picture | ||||
| Rated Capacity | 12KVA | 30kVA | 36kVA | 60kVA |
| Input Voltage | 380V | AC 380V, 50Hz | AC 380V, 50Hz | AC 380V, 50Hz |
| Input Current | 31.5A | 79A | 95A | 158A |
| Output Voltage | 6V | |||
| Output Current | 2000A | 5000A | 6000A | 10000A |
| Overall Dimension | L * W * H: 600 * 430 * 760 | |||
| Structural Type | Split type |
| Model | RDJB-802Y | RDJB-1600Y |
|---|---|---|
| AC Source | Phase current output (effective value): 0~40A/phase, accuracy 0.2% | Current range: 6x (0~30A)/phase, accuracy 0.2%. |
| AC Source | 3-phase parallel current output (effective value): 0~120A | 6-phase parallel current output: 180A |
| AC Source | Phase current working value for allowed long time (effective value): 10A | |
| AC Source | The maximum output power of each Phase: 420VA | The maximum output power of each Phase: 300VA |
| AC Source | Maximum output power of 3 parallel currents: 900VA | The maximum output power of 6 phases in parallel: 900VA |
| AC Source | Maximum permitted work time of 3 parallel current: 10s | Maximum permitted work time of 6 phases in parallel: 10s |
| AC Source | Frequency range: 0~1000Hz, accuracy: 0.001Hz | |
| AC Source | Harmonic time: 2~20 | |
| AC Source | Phase: 0~360°, accuracy: 0.1° | |
| DC Source | Current range: 0~±30A/phase, power: 300VA/phase, accuracy: 0.5% | Current range: 0~±20A/phase, power: 300VA/phase, accuracy: 0.5% |
| AC Voltage Source | Phase voltage output (effective value): 0~125V/phase, accuracy: 0.2% | |
| AC Voltage Source | Line voltage output (effective value): 0~250V | |
| AC Voltage Source | Phase voltage / Line voltage output power: 75VA/100VA | Phase voltage / Line voltage output power: 70VA/100VA |
| AC Voltage Source | Frequency range: 0~1000Hz, accuracy: 0.001Hz | |
| AC Voltage Source | Harmonic time: 2~20 | |
| AC Voltage Source | Phase: 0~360°, accuracy: 0.1° | |
| DC Voltage Source | Phase voltage output range: 0~±150V, accuracy: 0.5% | |
| DC Voltage Source | Line voltage output range: 0~±300V | |
| DC Voltage Source | Phase voltage / Line voltage output power: 90VA / 180VA | |
| Switching Terminal | Switch input terminals: 8 pairs | |
| Switching Terminal | Dead contact: 1~20mA, 24V active output inside the device | |
| Switching Terminal | Potential flip: 0~6V DC low-level 15~250V DC high-level | |
| Switching Terminal | Switch output terminals: 4 pairs, dead contact, rupturing capacity: 110V/2A, 220V/1A | |
| Time Measurement Range | 1ms ~ 9999s, accuracy: 1ms | |
| Power | AC220V±10% 50Hz 10A |
| Model | Model | RDHG-E |
|---|---|---|
| Test purpose | CT, PT | |
| Output | 0 ~ 180Vrms, 12Arms, 36A (peak value) | |
| Voltage measurement accuracy | ±0.1% | |
| CT transformation ratio measurement | Range | 1~10000 |
| CT transformation ratio measurement | Accuracy | ±0.2% |
| PT transformation ratio measurement | Range | 1~10000 |
| PT transformation ratio measurement | Accuracy | ±0.2% |
| Phase measurement | Accuracy | ±3min |
| Phase measurement | Resolution | 0.3min |
| Secondary winding resistance measurement | Range | 0~300Ω |
| Secondary winding resistance measurement | Accuracy | 1%±1mΩ |
| AC load measurement | Range | 0~300VA |
| AC load measurement | Accuracy | 1%±0.1VA |
| Input power supply voltage | AC220V±10%, 50Hz | |
| Work Environment | Temperature: – 10 ℃ ~ 50 ℃, humidity: ≤ 90% |
| Parameter | Value |
|---|---|
| Parameter | Specification |
| Rated Capacity | 36 kVA |
| Input Voltage | AC 380 V, 50 Hz |
| Input Current | 95 A |
| Output Voltage | 6 V |
| Output Current | 6000 A |
| Structural Type | Split Type |
| Working System | Designed for a 5-minute short-time working system |
| Intermittent Working Condition | Power-on time should be less than 2.5 minutes |
| Working Cycle | Greater than 10 minutes |
What a Relay Test Set Does in Protection Testing
A relay test set injects voltage and current signals into relay inputs to check relay operation and secondary wiring. Injection from the test set replaces the quantities the relay would see in service, so pickup, drop-out, timing and logic can be observed without energizing the primary circuit. A common workflow is to read the relay settings and the panel drawings, connect the test set to the relay terminals, inject the chosen quantities, compare the relay response with the expected values, and record the result.
The Wrindu RDJB series covers this workflow, and the range sits alongside the circuit breaker analyzers used to check the switchgear a relay controls. Buyers can send the relay type and the tests required through the inquiry form or by sales email and request a quotation.
Current Transformer Testing with a CT Analyzer
A CT analyzer is used for current transformer checks at the terminal box before commissioning or after secondary wiring changes. Current transformer testing covers ratio, polarity, excitation or volt-ampere characteristics, burden and secondary circuit inspection, with the primary left open and the secondary disconnected from the relay so the measured curves describe the transformer alone rather than the connected load.
Wrindu supplies the RDHG-D Multi-Functional CT PT Analyzer, which performs volt-ampere characteristics, ratios, polarity, inflection points and secondary-side circuit inspection. The spellings ctanalyzer and ct analyser are variants of CT analyzer and describe the same instrument and the same checks, so a buyer searching either term is looking at the same test work.
Relay Test Equipment for Field and Workshop Teams
Protection testing uses several instruments, each with a separate role. Relay testers apply voltage and current to relay inputs, CT analyzers characterize current transformers and their secondary circuits, and primary current injection equipment passes current through the primary path to prove the whole loop. Wrindu supplies the RDJB relay testers, the RDHG-D Multi-Functional CT PT Analyzer and the RDSL-82 series primary current injection test set for these roles.
- Relay testers suit panel work in the workshop and relay checks in a substation control room.
- CT analyzers are carried to the transformer terminal box, where the secondary cores are accessible.
- Primary current injection sets are used where the primary conductor can be taken out of service and loaded for the test.
- Test leads, test blocks and the panel drawings should be arranged before the test window opens.
Secondary Injection Test Set for Protection Schemes
A secondary injection test set injects voltage and current into relay inputs to test protection logic and secondary wiring, with the primary circuit left untouched. It suits settings changes, logic checks and panel wiring work, and cases where primary current is not practical. Primary injection sends current through the primary conductor and proves the current path as well as the relay, so the two methods answer different questions and are often run at different stages.
The RDJB relay testers are Wrindu relay test equipment for the secondary injection workflow, covering injection into relay inputs and the reading of the response. Teams that also run primary checks pair a relay tester with the RDSL-82 series, while transformer test equipment covers the transformer checks that follow.
How an order runs
- Send your requirements
- The equipment you need to test, its voltage level and the tests you plan to run.
- Selection and quotation
- Wrindu proposes matching tester models and accessories and sends a quotation.
- Inspection and delivery
- Equipment is inspected and packed before delivery; the delivery time is confirmed with the quotation.
- Warranty and training
- During the 12-month warranty, Wrindu provides free training, manuals, complaint response and software upgrades.
Request a quotation
Send the test object and voltage level; we will propose matching tester models.
Or write to sales@hipottestequipment.com