A protection relay test set injects voltage and current into protective relays to confirm they pick up, time and trip correctly. Wrindu supplies the RDJB series and the RDHG-D CT PT Analyzer for utility, substation and contractor protection testing work.

Request a tester quotation

Warranty
12-month warranty
Relay protection tester from Wrindu

Selecting a Protection Relay Test Set for Utility and Substation Work

A protection relay test set tests protective relays and secondary circuits by applying voltage and current to relay inputs and reading how the relay responds. Selection starts with phase count, then moves to output type, portability and the protection functions a team needs on site or in the workshop. Wrindu supplies the RDJB series microcomputer protection relay tester, which integrates microelectronic technology and offers high performance, cost-effectiveness and reliability, and the specification tables on this page list the models and their parameters.

Wrindu supplies these units for utility, substation and contractor protection work, and a quotation can be requested through the inquiry form on this page, the contact page or a sales email.

Protection relay test set models and specifications

Primary Current Injection Test Set specifications
ModelRDSL-82-2000ARDSL-82-5000ARDSL-82-6000ARDSL-82-10000A
Picture
Rated Capacity12KVA30kVA36kVA60kVA
Input Voltage380VAC 380V, 50HzAC 380V, 50HzAC 380V, 50Hz
Input Current31.5A79A95A158A
Output Voltage6V
Output Current2000A5000A6000A10000A
Overall DimensionL * W * H: 600 * 430 * 760
Structural TypeSplit type
6 Phase Relay Tester specifications
ModelRDJB-802YRDJB-1600Y
AC SourcePhase current output (effective value): 0~40A/phase, accuracy 0.2%Current range: 6x (0~30A)/phase, accuracy 0.2%.
AC Source3-phase parallel current output (effective value): 0~120A6-phase parallel current output: 180A
AC SourcePhase current working value for allowed long time (effective value): 10A
AC SourceThe maximum output power of each Phase: 420VAThe maximum output power of each Phase: 300VA
AC SourceMaximum output power of 3 parallel currents: 900VAThe maximum output power of 6 phases in parallel: 900VA
AC SourceMaximum permitted work time of 3 parallel current: 10sMaximum permitted work time of 6 phases in parallel: 10s
AC SourceFrequency range: 0~1000Hz, accuracy: 0.001Hz
AC SourceHarmonic time: 2~20
AC SourcePhase: 0~360°, accuracy: 0.1°
DC SourceCurrent range: 0~±30A/phase, power: 300VA/phase, accuracy: 0.5%Current range: 0~±20A/phase, power: 300VA/phase, accuracy: 0.5%
AC Voltage SourcePhase voltage output (effective value): 0~125V/phase, accuracy: 0.2%
AC Voltage SourceLine voltage output (effective value): 0~250V
AC Voltage SourcePhase voltage / Line voltage output power: 75VA/100VAPhase voltage / Line voltage output power: 70VA/100VA
AC Voltage SourceFrequency range: 0~1000Hz, accuracy: 0.001Hz
AC Voltage SourceHarmonic time: 2~20
AC Voltage SourcePhase: 0~360°, accuracy: 0.1°
DC Voltage SourcePhase voltage output range: 0~±150V, accuracy: 0.5%
DC Voltage SourceLine voltage output range: 0~±300V
DC Voltage SourcePhase voltage / Line voltage output power: 90VA / 180VA
Switching TerminalSwitch input terminals: 8 pairs
Switching TerminalDead contact: 1~20mA, 24V active output inside the device
Switching TerminalPotential flip: 0~6V DC low-level 15~250V DC high-level
Switching TerminalSwitch output terminals: 4 pairs, dead contact, rupturing capacity: 110V/2A, 220V/1A
Time Measurement Range1ms ~ 9999s, accuracy: 1ms
PowerAC220V±10% 50Hz 10A
CT And PT Analyzer specifications
ModelModelRDHG-E
Test purposeCT, PT
Output0 ~ 180Vrms, 12Arms, 36A (peak value)
Voltage measurement accuracy±0.1%
CT transformation ratio measurementRange1~10000
CT transformation ratio measurementAccuracy±0.2%
PT transformation ratio measurementRange1~10000
PT transformation ratio measurementAccuracy±0.2%
Phase measurementAccuracy±3min
Phase measurementResolution0.3min
Secondary winding resistance measurementRange0~300Ω
Secondary winding resistance measurementAccuracy1%±1mΩ
AC load measurementRange0~300VA
AC load measurementAccuracy1%±0.1VA
Input power supply voltageAC220V±10%, 50Hz
Work EnvironmentTemperature: – 10 ℃ ~ 50 ℃, humidity: ≤ 90%
RDSL-82-6000D Current Injection Test Equipment for Power Systems specifications
ParameterValue
ParameterSpecification
Rated Capacity36 kVA
Input VoltageAC 380 V, 50 Hz
Input Current95 A
Output Voltage6 V
Output Current6000 A
Structural TypeSplit Type
Working SystemDesigned for a 5-minute short-time working system
Intermittent Working ConditionPower-on time should be less than 2.5 minutes
Working CycleGreater than 10 minutes

What a Relay Test Set Does in Protection Testing

A relay test set injects voltage and current signals into relay inputs to check relay operation and secondary wiring. Injection from the test set replaces the quantities the relay would see in service, so pickup, drop-out, timing and logic can be observed without energizing the primary circuit. A common workflow is to read the relay settings and the panel drawings, connect the test set to the relay terminals, inject the chosen quantities, compare the relay response with the expected values, and record the result.

The Wrindu RDJB series covers this workflow, and the range sits alongside the circuit breaker analyzers used to check the switchgear a relay controls. Buyers can send the relay type and the tests required through the inquiry form or by sales email and request a quotation.

Current Transformer Testing with a CT Analyzer

A CT analyzer is used for current transformer checks at the terminal box before commissioning or after secondary wiring changes. Current transformer testing covers ratio, polarity, excitation or volt-ampere characteristics, burden and secondary circuit inspection, with the primary left open and the secondary disconnected from the relay so the measured curves describe the transformer alone rather than the connected load.

Wrindu supplies the RDHG-D Multi-Functional CT PT Analyzer, which performs volt-ampere characteristics, ratios, polarity, inflection points and secondary-side circuit inspection. The spellings ctanalyzer and ct analyser are variants of CT analyzer and describe the same instrument and the same checks, so a buyer searching either term is looking at the same test work.

Relay Test Equipment for Field and Workshop Teams

Protection testing uses several instruments, each with a separate role. Relay testers apply voltage and current to relay inputs, CT analyzers characterize current transformers and their secondary circuits, and primary current injection equipment passes current through the primary path to prove the whole loop. Wrindu supplies the RDJB relay testers, the RDHG-D Multi-Functional CT PT Analyzer and the RDSL-82 series primary current injection test set for these roles.

  • Relay testers suit panel work in the workshop and relay checks in a substation control room.
  • CT analyzers are carried to the transformer terminal box, where the secondary cores are accessible.
  • Primary current injection sets are used where the primary conductor can be taken out of service and loaded for the test.
  • Test leads, test blocks and the panel drawings should be arranged before the test window opens.

Secondary Injection Test Set for Protection Schemes

A secondary injection test set injects voltage and current into relay inputs to test protection logic and secondary wiring, with the primary circuit left untouched. It suits settings changes, logic checks and panel wiring work, and cases where primary current is not practical. Primary injection sends current through the primary conductor and proves the current path as well as the relay, so the two methods answer different questions and are often run at different stages.

The RDJB relay testers are Wrindu relay test equipment for the secondary injection workflow, covering injection into relay inputs and the reading of the response. Teams that also run primary checks pair a relay tester with the RDSL-82 series, while transformer test equipment covers the transformer checks that follow.

How an order runs

Send your requirements
The equipment you need to test, its voltage level and the tests you plan to run.
Selection and quotation
Wrindu proposes matching tester models and accessories and sends a quotation.
Inspection and delivery
Equipment is inspected and packed before delivery; the delivery time is confirmed with the quotation.
Warranty and training
During the 12-month warranty, Wrindu provides free training, manuals, complaint response and software upgrades.