SF6 Gas Analyzer: Purity, Moisture and Decomposition Testing

An SF6 gas analyzer checks the condition of SF6 in switchgear and gas-insulated equipment. Wrindu, based in Shanghai, supplies purity, moisture and decomposition testing instruments for substation work, with configurations matched to the compartment and readings you need.

Request a tester quotation

Warranty
12-month warranty
SF6 gas tester from Wrindu

What an SF6 Gas Analyzer Measures and How to Specify a Unit

An SF6 gas analyzer checks the condition of SF6 gas in switchgear and other gas-insulated equipment. It measures purity or concentration, moisture content expressed as dew point, and decomposition by-products such as SO2, H2S and CO. Purity supports dielectric strength and arc-quenching performance, moisture control protects insulation and limits corrosion, and decomposition readings show whether arcing or overheating has altered the gas. Wrindu, the brand of Rui Du Mechanical and Electrical (Shanghai) Co., Ltd., specializes in power testing equipment. Send compartment details, gases to be measured and site conditions through the inquiry form so the right configuration can be proposed.

An SF6 gas analyser is the same instrument as an SF6 gas analyzer; “analyser” is the British spelling, and both describe the same product category. When requesting a quotation, include equipment voltage class and gas compartment type, the readings needed—purity, moisture or decomposition products—whether the unit must be carried between bays, ambient and site conditions, and reporting needs. Use the inquiry form or sales email. Specifications are confirmed against the exact Wrindu model quoted.

SF6 gas analyzer models and specifications

SF6 Multifunctional Tester specifications
ModelRDZH-709 ARDZH-709B
Dew point detection moduleDew point detection module
Dew point range―80℃ ~ +20℃
Measurement accuracy±0.5℃
Micro water range0.05 ~ 23100 μL/L
Measurement response time(+20℃)-80℃ →20℃ 5s(63%),45s(90%) 20℃→-80℃ 10s(63%),240s(90%)
ResolutionDew point:0.1℃ Micro water:0.1ppm(100ppm ~ 1000ppm) 0.01ppm (10ppm ~ 100ppm)
Repeatability±0.2℃
Purity detection modulePurity detection module
Measurement range0~99.99%
Measurement accuracy±0.2%
Repeatability±0.1%
Resolution0.01%
Decomposition product detection moduleDecomposition product detection module
Measurement rangeSO2:0 ~ 100μL/L H2S:0 ~ 100μL/L CO: 0 ~ 1000μL/LSO2:0 ~ 100μL/L H2S:0 ~ 100μL/L CO: 0 ~ 1000μL/L HF: 0 ~ 10μL/L
Measurement accuracySO2 : when the measured value ≤10μL/L, the error±0.2μL/L when the measured value≥10μL/L, the error≤±3% H2S : when the measured value≤10μL/L, the error±0.2μL/L when the measured value≥10μL/L, the error≤±3% CO: when the measured value≤50μL/L, the error±0.5μL/L when the measured value≥50μL/L, the error≤±4%SO2 : when the measured value ≤10μL/L, the error±0.2μL/L when the measured value≥10μL/L, the error≤±3% H2S : when the measured value≤10μL/L, the error±0.2μL/L when the measured value≥10μL/L, the error≤±3% CO: when the measured value≤50μL/L, the error±0.5μL/L when the measured value≥50μL/L, the error≤±4% HF: the error of measured value≤±0.1μL /L
RepeatabilitySO2 : when the measured value≤10μL/L,the repeatability≤±0.1 when the measured value≥10μL/L,the repeatability≤±2% H2S : when the measured value≤10μL/L,the repeatability≤±0.1 when the measured value≥10μL/L,the repeatability≤±2% CO: when the measured value≤50μL/L,the repeatablity±0.3 when the measured value≥50μL/L,the repeatability≤±3%SO2 : when the measured value≤10μL/L,the repeatability≤±0.1 when the measured value≥10μL/L,the repeatability≤±2% H2S : when the measured value≤10μL/L,the repeatability≤±0.1 when the measured value≥10μL/L,the repeatability≤±2% CO: when the measured value≤50μL/L,the repeatablity±0.3 when the measured value≥50μL/L,the repeatability≤±3% HF: the repeatability of measured value≤±0.1
Resolution0.1μL/L
Other parametersOther parameters
Gas flowFlow regulation A regulated at 0.2l/min Flow regulation B regulated at 0.5-0.6l/min
Probe protectionstainless steel sintered filter screen
Working environmentTemperature -10℃ ~ +50℃ Humidity 0 ~ 90%RH
RDQH-64/350WF SF6 Gas Recovery and Purification System specifications
ParameterValue
technical requirement
1Compressor requirementsCustomized 30 cubic meters per hour SF6 high-pressure oil-free compressor
2vacuum pump64 cubic meters per hour, maximum vacuum ≤10pa
3Requirements for vacuum compressorsVacuum recovery compressor 20 cubic meters per hour, recovery final pressure<0.5mbar
4Liquid storage tank350L/50bar liquid storage tank;Built in refrigeration system.
5Dry filterIt adopts vacuum activation function, and the filter element can be replaced without disassembly
6Particle filterhave
7pressure displayDisplay unit: Mpa, both recovery final pressure and vacuum final pressure can be set
8External hose5-meter or optional 10-meter trachea with DN20 self -sealing joints at both ends
9instructionsEnglish operating manual
10working voltage415V/AC50Hz
11Touch Screen15inch touch screen, directly displaying parameters and flowcharts
Thermal Conductivity SF6 Gas Purity Analyzer specifications
ParameterValue
Picture
ModelRDCD-707
NameTechnical parameters
Measuring range0 ~ 100%
Measurement accuracy±0.1%
Repeatability±0.05%
Resolution0.01%
Sampling flow0.2L/min
Measuring time≤30S
Working environmentTemperature-10℃ ~ +50℃,humidity0 ~ 90%RH
Working power supplyLithium battery power supply, AC and DC dual-use, automatic switching, overcharge and over-discharge protection function
Volume and weight358×240×108(mm), weighing about 3.6 kg
SF6 Gas Purity Assessment Device specifications
ParameterValue
Picture
ModelRDCDF-706
Measuring rangepurity: 0 to 100%
Accuracypurity: ± 1%
Resolutionpurity: 0.1%
Repeatabilitypurity: ± 0.5%
Pressure range0 ~ 1MPa
Gas flow rate0.3 ~ 0.4L / min
Measuring time5 minutes
Operating voltage110 ~ 220VAC, AC and DC
Storage temperature rating-25 ~ + 70 ℃
Operating environmenttemperature: -25 ~ + 60 ℃
Power supplylithium battery, AC and DC dual-use, automatic switching, overcharge, and over-discharge protection lithium battery, AC and DC dual-use, automatic switching, overcharge and over-discharge protection

Choosing an SF6 Gas Analyzer for GIS, Circuit Breakers and Gas Compartments

Selection starts with the switchgear type and compartment arrangement. A GIS bay, a circuit breaker and other gas-insulated equipment can differ in access, gas volume and the readings that matter. Decide whether purity, moisture and decomposition products are all required or only part of the set. If the tester will move between bays, consider weight, carrying method and power source. Reporting needs shape the display, data storage and export functions. These are general selection points; the exact features and ranges are confirmed for the Wrindu model quoted. For related diagnostics, circuit breaker analyzers and partial discharge test equipment address different checks.

The RDQH-64/350WF is designed for SF6-filled electrical equipment such as GIS, circuit breakers and other high-voltage switchgear. The SF6 multifunctional tester is equipped with imported sensors for measuring humidity, purity and various gases such as SO2, H2S, CO and HF. Other model names shown in the specification tables on this page are RDZH-709 A and RDZH-709B. Each model should be considered against its own stated application and readings, not as a general claim for the range.

Wrindu has over 10 years of professional experience in global market service and has exported products to more than 120 countries, with main markets in South Asia, Southeast Asia and Africa. Rui Du Mechanical and Electrical (Shanghai) Co., Ltd. was established in 2014. During the 12-month warranty, Wrindu provides free training, manuals, complaint response and software upgrades. Its after-sales team offers installation, training and maintenance support, and maintenance and spare parts remain available after the warranty. OEM and ODM customized products are provided, and many listings show a minimum order of 1 set. T/T and PayPal are accepted in USD or CNY, with FOB and express delivery.

The normal order sequence is straightforward: send the test object, voltage level and tests needed; receive a selection proposal; place the order; complete pre-delivery inspection and packing; arrange shipping; and take part in training. The quoted Wrindu model remains the reference for the configuration supplied.

How an order runs

Send your requirements
The equipment you need to test, its voltage level and the tests you plan to run.
Selection and quotation
Wrindu proposes matching tester models and accessories and sends a quotation.
Inspection and delivery
Equipment is inspected and packed before delivery; the delivery time is confirmed with the quotation.
Warranty and training
During the 12-month warranty, Wrindu provides free training, manuals, complaint response and software upgrades.

Request a quotation

Send the test object and voltage level; we will propose matching tester models.

Or write to sales@hipottestequipment.com

* Required