AC Hipot Tester Series for Insulation Withstand Testing
Wrindu supplies AC hipot testers for insulation withstand checks in power systems, industry and research. The YDJ series AC hipot oil-immersed testing transformer is compact, lightweight and versatile, and model selection starts with the test object, voltage level and tests needed.
Request a quotation for this equipment
- Warranty
- 12-month warranty

AC Hipot Testers for Power-System and Industrial Insulation Checks
An AC hipot tester is equipment that applies AC high voltage to insulation for withstand testing. In power-system and industrial insulation checks, it stresses cables, bushings, transformers, motors and other insulation to confirm that the insulation can hold the applied voltage without breakdown. Wrindu supplies the YDJ series AC hipot oil-immersed testing transformer, which is compact, lightweight and versatile, and is suited to high-voltage insulation tests in power systems, industries and research institutions.
For model selection and quotation, send your test object, required voltage level and the tests you need through the inquiry form or sales email. Wrindu offers the YDJ series alongside other hipot testers, and the dielectric withstand testing guide explains the test in more detail.

AC hipot test set, view 2 
AC hipot test set, view 3
AC hipot tester models and specifications
| Parameter | Value |
|---|---|
| Oil Immersed Test Transformer | Oil Immersed Test Transformer |
| Capacity(kVA) | 5 |
| Output voltage (kV) | AC 100 |
| Output current (mA) | AC 50 |
| Input voltage (V) | 200 |
| Input current (A) | 25 |
| Transformation ratio | 1000 |
| (HVwinding /instrument) | 1000 |
| Temperature rise-30min (℃) | 10 |
| Manual Console | Manual Console |
| Capacity(kVA) | 5 |
| Input voltage (V) | AC 220,50Hz |
| Input current (A) | 22 |
| Output voltage (V) | 0-200 |
| Output current (A) | 25 |
| operating mode | Manual |
| Parameter | Value | |
|---|---|---|
| Oil Immersed Test Transformer | Oil Immersed Test Transformer | |
| Capacity(kVA) | 5 | |
| Output voltage (kV) | 50 (AC) | 70 (DC) |
| Output current (mA) | 100 (AC) | 71.42 (DC) |
| Input voltage (V) | 200V | |
| Input current (A) | 25A | |
| Impedance drop | <10% | |
| No-load current | <5% | |
| Manual Control Box | Manual Control Box | |
| Capacity(kVA) | 5 | |
| Input voltage (V) | 220V | |
| Input current (A) | 22.7A | |
| Output voltage (V) | 0-250 | |
| Output current (A) | 20 | |
| operating mode | Manual |
| Model | YDQ-10kVA/100kV | YDQ-20kVA/100kV |
|---|---|---|
| Capacity | 10 kVA | 20 kVA |
| Low voltage side | Voltage 200 V, current 50 A | Voltage 400 V, current 50 A |
| High voltage side | Voltage 100 kV, current 200 mA | |
| Measurement ratio | 1000 | |
| Temperature rise | 50 ℃ | |
| Note | The products can be customized according to the user’s requirements. |
| Parameter | Value | ||||||
|---|---|---|---|---|---|---|---|
| Specification | Capacity kVA | Low voltage side | Low voltage side | High voltage side | High voltage side | Measurement ratio | Temperature rise ℃ |
| Specification | Capacity kVA | Voltage V | Current A | Voltage kV | Current mA | Measurement ratio | Temperature rise ℃ |
| 6/50 | 6 | 200 | 30 | 50 | 120 | 500:1 | 50 |
| 10/50 | 10 | 200 | 50 | 50 | 200 | 500:1 | 50 |
| 15/50 | 15 | 400 | 37.5 | 50 | 300 | 500:1 | 50 |
| 20/50 | 20 | 400 | 50 | 50 | 400 | 500:1 | 50 |
| 30/50 | 30 | 400 | 75 | 50 | 600 | 500:1 | 50 |
| 50/50 | 50 | 400 | 125 | 50 | 1000 | 500:1 | 50 |
| 10/100 | 10 | 200 | 50 | 100 | 100 | 1000:1 | 50 |
| 15/100 | 15 | 400 | 37.5 | 100 | 150 | 1000:1 | 50 |
| 20/100 | 20 | 400 | 50 | 100 | 200 | 1000:1 | 50 |
| 30/100 | 30 | 400 | 75 | 100 | 300 | 1000:1 | 50 |
| 50/100 | 50 | 400 | 125 | 100 | 500 | 1000:1 | 50 |
| 50/200 | 50 | 400 | 125 | 200 | 250 | 2000:1 | 50 |
| 50/300 | 50 | 400 | 125 | 300 | 166 | 3000:1 | 50 |
| Model | YDJ series | ||||||
|---|---|---|---|---|---|---|---|
| Picture | |||||||
| Specification | Capacity kVA | High voltage side | High voltage side | Low voltage side | Low voltage side | Measurement ratio | Temperature rise ℃ (30 mins) |
| Specification | Capacity kVA | Voltage kV | Current mA | Voltage V | Current A | Measurement ratio | Temperature rise ℃ (30 mins) |
| 5/50 | 5 | 50 | 100 | 200 | 25 | 500 | 10 |
| 10/50 | 10 | 50 | 200 | 200 | 50 | 500 | 10 |
| 20/50 | 20 | 50 | 400 | 400 | 50 | 500 | 10 |
| 30/50 | 30 | 50 | 600 | 400 | 75 | 500 | 10 |
| 50/50 | 50 | 50 | 1000 | 400 | 125 | 500 | 10 |
| 5/100 | 5 | 100 | 50 | 200 | 25 | 1000 | 10 |
| 10/100 | 10 | 100 | 100 | 200 | 50 | 1000 | 10 |
| 20/100 | 20 | 100 | 200 | 400 | 50 | 1000 | 10 |
| 30/100 | 30 | 100 | 300 | 400 | 75 | 1000 | 10 |
| 50/100 | 50 | 100 | 500 | 400 | 125 | 1000 | 10 |
| 50/200 | 50 | 200 | 250 | 400 | 125 | 1000 | 10 |
| 50/300 | 50 | 300 | 170 | 400 | 125 | 3000 | 10 |
How AC Hipot Testing Works
During AC hipot testing, a controlled AC high voltage is applied to the insulation under test while leakage current is monitored. The test set raises the voltage to the chosen level, holds it for the planned period, and observes whether the insulation withstands the stress or breaks down. A stable reading with no breakdown indicates insulation strength for that test condition; a sudden current rise or breakdown requires the test to be stopped and the cause investigated.
AC hipot is shorthand for AC high-potential testing. An AC hipot test uses an AC high-voltage source to stress insulation, so the term describes the same purpose: checking whether insulation can withstand an applied AC voltage. For buyers who need AC hipot equipment for high-voltage insulation tests in power systems, industries and research institutions, Wrindu supplies the YDJ series AC hipot oil-immersed testing transformer.
Safe setup starts with a clear test area, discharged and isolated equipment, grounded test connections, and a guard or barrier around the test object. The operator should confirm settings before energizing, watch for abnormal current, and discharge the object after the test. Results are interpreted against the intended test condition and the insulation’s behavior during the hold period, not as a substitute for a full insulation assessment.
Choosing an AC Hipot Test Set
An AC hipot test set is selected by matching its test voltage and current capacity to the insulation under test. Review the controls, safety provisions, portability and maintenance support as well as the intended use in power-system, industrial or research work. The test set should suit the test object, the voltage level and the tests you need, rather than being chosen by model name alone.
- Confirm the test object and its insulation requirements
- Match test voltage and current capacity to the load
- Review controls, interlock and discharge provisions
- Check portability and site power requirements
- Confirm maintenance and spare-parts support
Wrindu supplies the YDJ series AC hipot oil-immersed testing transformer, which is compact, lightweight and versatile for high-voltage insulation tests in power systems, industries and research institutions. To receive a quotation, send your test object, voltage level and tests needed through the inquiry form or sales email. Wrindu can then propose a suitable configuration for model selection and quotation.
Wrindu Supply and Service for AC Hipot Testers
During the 12-month warranty, Wrindu provides free training, manuals, complaint response and software upgrades. The after-sales team offers installation, training and maintenance support, and maintenance and spare parts remain available after the warranty. These services support the AC hipot tester series and the power testing equipment Wrindu supplies.
Wrindu is the brand name of Rui Du Mechanical and Electrical (Shanghai) Co., Ltd., which specializes in power testing equipment. Established in 2014, Wrindu has over 10 years of professional experience in global market service and has exported products to more than 120 countries. Many Wrindu listings on its Alibaba store show a minimum order of 1 set, and Wrindu provides OEM and ODM customized products.
How an order runs
- Send your requirements
- The equipment you need to test, its voltage level and the tests you plan to run.
- Selection and quotation
- Wrindu proposes matching tester models and accessories and sends a quotation.
- Inspection and delivery
- Equipment is inspected and packed before delivery; the delivery time is confirmed with the quotation.
- Warranty and training
- During the 12-month warranty, Wrindu provides free training, manuals, complaint response and software upgrades.
Request a quotation
Tell us the voltage, capacity or cable length you need to test.