Wrindu VLF Tester for Cable Hipot and HV Cable Testing
A VLF tester applies very-low-frequency AC voltage to cable insulation so withstand strength can be checked on site. Wrindu supplies VLF hipot testers and related cable test equipment, with model selection based on your cable details.
Request a quotation for this equipment
- Warranty
- 12-month warranty

What a VLF Tester Does in Cable Withstand Testing
A VLF tester is a very-low-frequency AC withstand voltage test set used to check cable insulation. It raises test voltage gradually at a frequency well below power frequency, holds it at the selected level, then reduces it, so the insulation sees controlled AC stress rather than a sudden step. It is used after installation, after joint or termination work, and when an older cable must be checked before energising. The low frequency keeps charging current small, so long cables can be tested with portable equipment.
Wrindu is the brand name of Rui Du Mechanical and Electrical (Shanghai) Co., Ltd., a supplier of power testing equipment. The company was established in 2014 and has over 10 years of professional experience in global market service. Send your cable type, voltage level and the tests you need, and we will propose a matching model from the hipot tester range.

VLF hipot tester, view 2 
VLF hipot tester, view 3
VLF hipot tester models and specifications
| Model | RDVLF-50 | RDVLF-80 |
|---|---|---|
| Output Voltage Ratings | 50 kV | 80 kV |
| Output Frequency | 0.1Hz, 0.05Hz, 0.02Hz | |
| Load Capacity | 0.1Hz maximum 1.1µF 0.05Hz maximum 2.2µF 0.02Hz maximum 5.5µF | |
| Measurement Accuracy | 3% | |
| Positive and Negative Voltage Peak Errors | ≤ 3% | |
| Voltage Waveform Distortion | ≤ 5% | |
| Use Condition: Temperature | -10℃~+40℃; Humidity: ≤ 85%RH | |
| Power Supply Fuse Tub | 10A | |
| Power | AC 50Hz, 220V ±5% |
| No. | Technical Parameter | Specification |
|---|---|---|
| 1 | Power Supply | 220V ± 10% AC (110V can be customized), 50/60Hz, Single Phase |
| 2 | AC Output Voltage (Peak) | 40 kV |
| 3 | Output Frequency | 0.1Hz, 0.05Hz, 0.02Hz, 0.01Hz (Auto Variable Frequency) |
| 4 | Load Capacity | 0.5μF @ 0.1Hz; 1.0μF @ 0.05Hz; 2.5μF @ 0.02Hz; 5.0μF @ 0.01Hz |
| 5 | Frequency Stability | Frequency fluctuation < 0.5% |
| 6 | AC Voltage Measurement Accuracy | ±3% |
| 7 | AC Voltage Measurement Resolution | 0.1kV |
| 8 | AC Current Measurement Accuracy | ±3% |
| 9 | AC Current Measurement Range | 0–20mA |
| 10 | AC Current Measurement Resolution | 0.1mA |
| 11 | Positive and Negative Voltage Peak Error | ≤3% |
| 12 | Voltage Waveform Distortion | ≤3% |
| 13 | Construction Type | 40kV Integrated Device |
| 14 | DC Leakage Current Measurement (Optional) | Supported |
| 15 | DC Output Rated Voltage | +40kV |
| 16 | DC Voltage Accuracy | 3% |
| 17 | DC Leakage Current Range | 0–2000μA |
| 18 | DC Leakage Current Resolution | 1μA |
| 19 | DC Leakage Current Accuracy | 3% |
| 20 | Operating Temperature | Indoor and Outdoor: -10℃ to +50℃ |
| 21 | Operating Humidity | ≤85% |
| Parameter | Value |
|---|---|
| Parameter | Specification |
| Power Supply | 220V ±10% AC (110V optional), 50/60Hz, single phase |
| AC Output Voltage (Peak) | 80 kV |
| Output Frequency | 0.1Hz, 0.05Hz, 0.02Hz, 0.01Hz (Auto variable frequency) |
| Load Capacity | 0.5μF @ 0.1Hz; 1.0μF @ 0.05Hz; 2.0μF @ 0.02Hz; 4.0μF @ 0.01Hz |
| Frequency Stability | Frequency fluctuation < 0.5% |
| AC Voltage Measurement Accuracy | ±3% |
| AC Voltage Resolution | 0.1kV |
| AC Current Measurement Accuracy | ±3% |
| AC Current Range / Resolution | 0–20mA / 0.1mA |
| Positive & Negative Voltage Peak Error | ≤3% |
| Voltage Waveform Distortion | ≤3% |
| System Configuration | 1 × 40kV integrated unit + 1 × 40kV external booster |
| DC Leakage Current Measurement (Optional) | Available |
| DC Output Voltage | +80kV |
| DC Voltage Accuracy | 3% |
| DC Leakage Current Range | 0–2000μA |
| DC Leakage Current Resolution | 1μA |
| DC Leakage Current Accuracy | 3% |
| Operating Temperature | -10°C to +50°C (Indoor & outdoor use) |
| Operating Humidity | ≤85% RH |
| Parameter | Value |
|---|---|
| Item | Specification |
| Power Supply | 220V ± 10% AC (110V customizable), 50/60Hz, single phase |
| AC Output Peak Voltage | 1 ~ 60 KV |
| Output Frequency | 0.1Hz, 0.05Hz, 0.02Hz, 0.01Hz (auto variable frequency) |
| Load Capacity | 0.5μF @ 0.1Hz; 1.0μF @ 0.05Hz; 2.5μF @ 0.02Hz; 5.0μF @ 0.01Hz |
| Frequency Stability | Fluctuation < 0.5% |
| AC Voltage Measurement Accuracy | ±3% |
| AC Voltage Measurement Resolution | 0.1KV |
| AC Current Measurement Accuracy | ±3% |
| AC Current Measurement Range & Resolution | 0 ~ 20mA, 0.1mA |
| Positive & Negative Voltage Peak Error | ≤3% |
| Voltage Waveform Distortion | ≤3% |
| Construction | 1×60KV integrated device |
| Operating Ambient Temperature | -10℃ ~ +50℃ (indoor & outdoor) |
| Operating Ambient Humidity | ≤85% |
| VLF tgδ Test Technical Indexes | 1. Test voltage range: 1 ~ Rated value (60KV) 2. Measurement voltage accuracy: 1% 3. Dielectric loss test frequency: 0.1Hz 4. Dielectric loss measurement range: 0.01×10⁻³ ~ 655.35×10⁻³ 5. Dielectric loss accuracy: 1×10⁻⁴ 6. Dielectric loss resolution: 1×10⁻⁵ 7. Capacitance measurement range: 0.001μF ~ 10μF 8. Capacitance resolution: 0.001μF 9. Current measurement range: 0 ~ 20mA 10. Current resolution: 0.1mA |
| VLF PD Test Technical Indexes (Optional) | 1. Partial discharge measurement range: 1 pC ~ 5000 pC 2. Partial discharge detection resolution: 1 pC 3. PD measurement accuracy: 3% 4. Capacitance range: 0.001μF ~ 10μF 5. Sampling bits: 12 bits 6. Sampling speed: 200M/S 7. Test voltage: 0 ~ Rated value (KV) |
| DC Leakage Current Measurement (Optional) | 1. DC output rated voltage: +60KV 2. DC voltage accuracy: 3% 3. Leakage current range: 0 ~ 2000μA (customizable) 4. DC current resolution: 1μA 5. DC current accuracy: 3% |
Choosing a VLF Hipot Tester for Cable Work
A VLF hipot tester combines a very-low-frequency AC source with a hipot withstand test: the source produces the low-frequency voltage, the hipot section raises it to the chosen level, meters leakage current and cuts the output when a limit is reached. Compare units on these points:
- Cable type and expected capacitance, which set the current the source must supply
- Test mode: AC withstand alone, or AC with tan delta, capacitance and partial discharge measurement
- Portability and site power, since hipot work often happens in trenches and substations
- Safety controls: earthing, discharge, interlocks and an emergency stop
- Storage and export of test results
- Support for the voltage levels and cable lengths in your test plan
VLF hipot testing is an AC withstand test run at very low frequency. The stress reverses polarity each cycle, which is closer to service conditions than a direct voltage, and the low frequency keeps current draw manageable on site. DC hipot testing charges the insulation in one polarity and holds it: a different stress that can leave trapped charge. The right Wrindu model and the procedure depend on the cable and on what the test must prove.
Wrindu also supplies a multi-functional VLF hipot tester with tan delta and capacitance measurement; partial discharge testing and DC leakage measurement are optional configurations of that model. The RDVLF-Z80Y is a VLF AC withstand voltage tester for cable hipot work, and portable VLF high voltage test equipment is offered for cable and transformer testing. Send cable details for a model recommendation.
How Hipot Cable Testing and Tester Selection Work
Hipot cable testing applies an elevated test voltage to cable insulation for a set period to prove the insulation withstands more than it meets in service. The cable is isolated, proved dead and discharged, the screens and the conductors not under test are earthed, and the test set is earthed locally, with barriers keeping people clear of terminations. Voltage is raised at a controlled rate, held, then reduced, and the cable discharged and earthed before it is touched.
A cable that holds the test voltage without breakdown passes the withstand check. A voltage collapse, a rising leakage current or audible discharge calls for further investigation of the cable insulation and joints before the cable returns to service. Wrindu supplies hipot sets for this work; the dielectric withstand test guide covers method background, and DC hipot testers are the direct-voltage option.
For field use, a hipot cable tester is judged on test voltage range and the cable load it can drive, weight and handling, safety features such as earthing and discharge, and how results are stored. Share your cable type, length and test goal and Wrindu will recommend a model for your work.
Where VLF Testing Fits in HV Cable Testing
HV cable testing covers several jobs. Insulation withstand testing proves that a cable can take electrical stress, while fault diagnosis and route or fault location find where a weakness sits. VLF hipot testing is one withstand-test method; DC withstand testing, partial discharge inspection and fault pre-location are separate activities with their own equipment.
- The RDCD series cable fault testing system
- The RDCD-750 cable fault pre-locator
- The RDCD-II-503D buried cable detector
- The RDCD-C integrated mobile cable fault diagnosis system
- DC withstand voltage test sets for cables, transformers, arresters and switchgear
Send the cable type, voltage level and the tests you need, including fault location, and Wrindu will propose equipment for the work.
Range, Ordering and Support for Wrindu VLF Testers
The specification tables on this page list the VLF tester models Wrindu supplies. Many Wrindu product listings show a minimum order of 1 set, and OEM and ODM customisation is available. Payment is by T/T or PayPal in USD or CNY; delivery terms are FOB, with express delivery also offered (nearest port: Shanghai).
Normal service runs from your test requirements to a selection proposal, order, pre-delivery inspection and packing, shipping and training. Wrindu provides a 12-month warranty with free training, manuals, complaint response and software upgrades, and after-sales support covers installation, training and maintenance, with spare parts available after the warranty. Contact the team with your cable details.
How an order runs
- Send your requirements
- The equipment you need to test, its voltage level and the tests you plan to run.
- Selection and quotation
- Wrindu proposes matching tester models and accessories and sends a quotation.
- Inspection and delivery
- Equipment is inspected and packed before delivery; the delivery time is confirmed with the quotation.
- Warranty and training
- During the 12-month warranty, Wrindu provides free training, manuals, complaint response and software upgrades.
Request a quotation
Tell us the voltage, capacity or cable length you need to test.
Or write to sales@hipottestequipment.com